Bot Detector
IJPC Seal
Download FREE Sample Issue or Article
LEARN MORE
Subscribe Today
A subscription to IJPC provides on-line access to full-text, full-color, printable PDF copies of your subscribed issues, individual articles, and purchased archives.

Prolonged In-use Stability of Diluted Atezolizumab in Commercial Intravenous Bags

Author(s):  Hui Ada, Yin Jian, Liu Wei, Zheng Kai

Issue:  May/Jun 2021 - Volume 25, Number 3
View All Articles in Issue

Page(s):  246-257

Prolonged In-use Stability of Diluted Atezolizumab in Commercial Intravenous Bags Page 1
Prolonged In-use Stability of Diluted Atezolizumab in Commercial Intravenous Bags Page 2
Prolonged In-use Stability of Diluted Atezolizumab in Commercial Intravenous Bags Page 3
Prolonged In-use Stability of Diluted Atezolizumab in Commercial Intravenous Bags Page 4
Prolonged In-use Stability of Diluted Atezolizumab in Commercial Intravenous Bags Page 5
Prolonged In-use Stability of Diluted Atezolizumab in Commercial Intravenous Bags Page 6
Prolonged In-use Stability of Diluted Atezolizumab in Commercial Intravenous Bags Page 7
Prolonged In-use Stability of Diluted Atezolizumab in Commercial Intravenous Bags Page 8
Prolonged In-use Stability of Diluted Atezolizumab in Commercial Intravenous Bags Page 9
Prolonged In-use Stability of Diluted Atezolizumab in Commercial Intravenous Bags Page 10
Prolonged In-use Stability of Diluted Atezolizumab in Commercial Intravenous Bags Page 11
Prolonged In-use Stability of Diluted Atezolizumab in Commercial Intravenous Bags Page 12

Download in electronic PDF format for $75

Abstract:  The programmed death-ligand 1 checkpoint inhibitor, atezolizumab is a monoclonal antibody that is indicated for the treatment of several cancers. Prior to administration, atezolizumab is diluted in normal saline (0.9% sodium chloride) in polyvinylchloride or polyolefin infusion bags. The objective of the studies reported in this paper was to evaluate the stability of atezolizumab diluted to 2.4 mg/mL and 9.6 mg/mL (Study 1), and 16.8 mg/mL (Study 2) in intravenous bags containing normal saline and stored for up to 12 months. Atezolizumab was withdrawn from commercial vials (1,200 mg/20 mL or 840 mg/14 mL) under aseptic conditions and added to infusion bags containing normal saline with target concentrations of 2.4 mg/mL, 9.6 mg/mL, and 16.8 mg/mL. Bags were stored at 30°C for 24 hours with exposure to ambient light, then at 2°C to 8°C for up to 12 months protected from light. 10-mL samples were withdrawn at selected time points and evaluated by analytical assays for color, opalescence, and clarity; visible and subvisible particulates; pH; protein concentration by ultraviolet spectrophotometric analysis; size-exclusion high-performance liquid chromatography; ion-exchange high-performance liquid chromatography; non-reduced capillary electrophoresis-sodium dodecyl sulfate; and potency assays. No substantial changes in atezolizumab product quality were apparent by any measure related to any analytical assay in either study after 3 months of storage at 2°C to 8°C. No new peaks were observed on size-exclusion high-performance liquid chromatography, ion-exchange high-performance liquid chromatography, or non-reduced capillary Funding Acknowledgment This study was funded by Genentech, Inc., South San Francisco, California. electrophoresis-sodium dodecyl sulfate profiles of diluted atezolizumab after the extended storage of 12 months at 2°C to 8°C. In Study 1, a decreasing trend in ion-exchange high-performance liquid chromatography main peak area was detected in samples from polyvinylchloride bags containing 2.4 mg/mL atezolizumab; and substantial changes were observed at 12 months in samples from polyvinylchloride bags containing 2.4 mg/mL and 9.6 mg/mL atezolizumab. In Study 2, decreasing trends in main peak areas were detected by size-exclusion high-performance liquid chromatography analyses, ion-exchange high-performance liquid chromatography analyses, and nonreduced capillary electrophoresis-sodium dodecyl sulfate analyses of samples stored in polyvinylchloride bags, where substantial changes were observed in size exclusion high-performance liquid chromatography main peak area at 12 months and in ion-exchange high-performance liquid chromatography main peak areas at the 6-month and subsequent time points. Decreasing trends in main peak areas were detected by ion-exchange high-performance liquid chromatography analyses and non-reduced capillary electrophoresis-sodium dodecyl sulfate analyses of samples taken from polyolefin bags, where substantial changes were observed in ion-exchange high-performance liquid chromatography main peak areas at 6 and 12 months. In conclusion, atezolizumab diluted to 2.4 mg/mL to 16.8 mg/mL in 0.9% sodium chloride remains physicochemically stable when stored for 24 hours at 30°C, followed by 3 months at 2°C to 8°C in polyvinylchloride and polyolefin infusion bags.

Related Keywords: atezolizumab, programmed death ligand 1 checkpoint inhibitor, monoclonal antibody, cancer treatment, stability, infusion bags

Related Categories: CANCER AND AIDS, PEER-REVIEWED, STABILITIES, COMPATIBILITIES, ALLERGY/IMMUNOLOGY/INFLAMMATION, STORAGE

Printer-Friendly Version



Related Articles from IJPC
Title/Author
(Click for Abstract / Details / Purchase)
Issue/​Page
View/Buy
Prolonged In-use Stability of Diluted Atezolizumab in Commercial Intravenous Bags
Hui Ada
, Yin Jian, Liu Wei, Zheng Kai
May/Jun 2021
Pg. 246-257

Prolonged In-use Stability of Reconstituted Herceptin in Commercial Intravenous Bags
Nalenz Heiko
, Köpf Ellen, Dietel Elke
Sep/Oct 2018
Pg. 417-423

In-use Stability of Ceftaroline Fosamil in Elastomeric Home Infusion Systems and MINI-BAG Plus Containers
Bhattacharya Sisir
, Parekh Satish, Dedhiya Mahendra
Sep/Oct 2015
Pg. 432-436

Physiochemical Stability of Diluted Trastuzumab Infusion Solutions in Polypropylene Infusion Bags
Kaiser Jeanette
, Kramer Irene
Nov/Dec 2011
Pg. 515-520

Stability of Gentamicin Sulfate and Tobramycin Sulfate in AutoDose Infusion System Bags
Xu Quanyun A
, Trissel Lawrence A, Saenz Christopher A, Ingram Delshalonda S
Mar/Apr 2002
Pg. 152-154

Stability of Dexmedetomidine in 0.9% Sodium Chloride in Two Types of Intravenous Infusion Bags
Marquis Kathleen
, Hohlfelder Benjamin, Szumita Paul M
Sep/Oct 2017
Pg. 436-439

Stability of Dexmedetomidine in Polyvinyl Chloride Bags Containing 0.9% Sodium Chloride Intended for Subcutaneous Infusions
Wolfe Amanda
, Zhang Jeremy, Lapenskie Julie, Downar James, Kanji Salmaan
Jul/Aug 2021
Pg. 330-335

Stability of Ampicillin Sodium, Nafcillin Sodium, and Oxacillin Sodium in AutoDose Infusion System Bags
Zhang Yanping
, Trissel Lawrence A
May/Jun 2002
Pg. 226-229

Stability of Amikacin Sulfate in AutoDose Infusion System Bags
Zhang Yanping
, Trissel Lawrence A
May/Jun 2003
Pg. 230-232

Sensitization Therapy for Warts
Kuntz Rachael
Jul/Aug 2003
Pg. 266-270

Antineoplastic Drug Contamination on the Outside of Prepared Infusion Bags
Breukels Oscar
, van der Gronde Toon, Simons-Sanders Kathleen, Crul Mirjam
Jul/Aug 2018
Pg. 345-349

Effect of Freezing, Long-Term Storage and Microwave Thawing on the Stability of Tramadol in 5% Dextrose Infusion in Polyvinyl Chloride Bags
Lebrun John
, Hecq Jean-Daniel, Vanbeckbergen Danielle, Jamart Jacques, Galanti Laurence M
Mar/Apr 2004
Pg. 156-159

Stability of Clindamycin Phosphate in AutoDose Infusion System Bags
Xu Quanyun A
, Trissel Lawrence A
Mar/Apr 2003
Pg. 149-151

Zinc Content of Commercial Diluents Widely Use in Drug Admixtures Prepared for Intravenous Infusion
Desai Narendra R
, Shah Syed M, Koczone Julianna, Vencl-Joncic Maja, Sisto Christopher, Ludwig Stephen A
Sep/Oct 2007
Pg. 426-432

Basics of Compounding for Raynaud's Disease
Glasnapp Andrew
Jul/Aug 2003
Pg. 288-291

Chemical Stability of Fentanyl in Polypropylene Syringes and Polyvinylchloride Bags
Donnelly Ronald F
Nov/Dec 2005
Pg. 482-483

Long-term Stability of Esomeprazole in 5% Dextrose Infusion Polyolefin Bags at 5°C ± 3°C after Microwave Freeze-thaw Treatment
Hecq Jean-Daniel
, Rolin Catherine, Godet Marie, Gillet Patricia, Jamart Jacques, Galanti Laurence M
Nov/Dec 2015
Pg. 521-524

Stability of Fentanyl Citrate in Polyolefin Bags
Donnelly Ronald F
Nov/Dec 2016
Pg. 514-516

Stability of Morphine Sulfate in Polypropylene Infusion Bags for Use in Patient-Controlled Analgesia Pumps for Postoperative Pain Management
Nguyen-Xuan Tho
, Griffiths William, Kern Christian, Van Gessel Elisabeth, Bonnabry Pascal
Jan/Feb 2006
Pg. 69-73

Effect of Freezing, Long-Term Storage, and Microwave Thawing on the Stability of Cefepime in 5% Dextrose Infusion Polyvinyl Chloride Bags
Schlesser Vincent
, Hecq Jean-Daniel, Vanbeckbergen Danielle, Jamart Jacques, Galanti Laurence M
Sep/Oct 2002
Pg. 391-394

Return to Top