Bot Detector
IJPC Seal
Download FREE Sample Issue or Article
LEARN MORE
Subscribe Today
A subscription to IJPC provides on-line access to full-text, full-color, printable PDF copies of your subscribed issues, individual articles, and purchased archives.

Quantitation of Testosterone-Cypionate-in-Oil Injection using High Performance Liquid Chromatography

Author(s):  Gupta Vishnu D, Pramar Y

Issue:  Jul/Aug 1999 - Compounding Parenteral Products
View All Articles in Issue

Page(s):  314-315

Quantitation of Testosterone-Cypionate-in-Oil Injection using High Performance Liquid Chromatography Page 1
Quantitation of Testosterone-Cypionate-in-Oil Injection using High Performance Liquid Chromatography Page 2

Download in electronic PDF format for $75

Abstract:  A high-performance liquid chromatography assay method for the quantitation of testosterone-cypionate-in-oil injection has been developed. The assay method is very simple, accurate and precise, with a percent relative standard deviation of 1.2 based on five readings. The extraction procedure is very simple compared with a very tedious and time-consuming procedure given in the United States Pharmacopoeia/National Formulary. The USP-NF assay method is based on gas chromatography. The benzyl alcohol (preservative) did not interfere with the assay procedure. The newly developed method could not be applied to the quantitation of testosterone enanthate since the results were consistently low (~87%). The average recovery of testosterone cypionate from a commercial dosage form was 98.7%.

Related Keywords: gas chromatography, high-performance liquid chromatography, injection, testosterone cypionate

Related Categories: HRT, PEER-REVIEWED

Printer-Friendly Version



Related Articles from IJPC
Title/Author
(Click for Abstract / Details / Purchase)
Issue/​Page
View/Buy
Quantitation of Testosterone-Cypionate-in-Oil Injection using High Performance Liquid Chromatography
Gupta Vishnu D
, Pramar Y
Jul/Aug 1999
Pg. 314-315

Quantitation of Testosterone Propionate in an Injection Using High Performance Liquid Chromatography
Gupta Vishnu D
Mar/Apr 1999
Pg. 158-159

Quality-Control Analytical Methods: High-Performance Liquid Chromatography
Kupiec Thomas C
May/Jun 2004
Pg. 223-227

Quantitation of Testosterone in Suspension using High Performance Liquid Chromatography
Gupta Vishnu D
May/Jun 1999
Pg. 239-240

Quality-Control Analytical Methods: Gas Chromatography
Kupiec Thomas C
Jul/Aug 2004
Pg. 305-309

Stability of an Oral Liquid Dosage Form of Trovafloxacin Mesylate and Its Quantitation in Tablets Using High-Performance Liquid Chromatography
Gupta Vishnu D
May/Jun 2000
Pg. 233-235

Testosterone Cypionate 100-mg/mL Injection
Allen Loyd V Jr
Jan/Feb 2013
Pg. 73

Stability of Acetyl-L-carnitine in 5% Dextrose Using a High-Performance Liquid Chromatography–Mass Spectrometry Times 2 Method
Zhang Yang
, Jiang Hongliang, Hutson Paul
Mar/Apr 2012
Pg. 170-173

A New High-Performance Liquid Chromatographic Method for Fludarabine and Fludarabine Phosphate Compounded in Liposomes
Abang Anthony M
, Abbas S Ali, Pham Trinh, Lambros Maria Polikandritou
Jul/Aug 2001
Pg. 320-322

Development and Application of a High-Performance Liquid Chromatography Stability-Indicating Assay for Beyond-Use Date Determination of Compounded Topical Gels Containing Multiple Active Drugs
Gorman Gregory
, Sokom Simara, Coward Lori, Arnold John J
Mar/Apr 2017
Pg. 164-170

Using Hospital Laboratory Services to Perform Quality-control Testing on Compounded Preparations
Donnelly Ronald F
Sep/Oct 2015
Pg. 383-386

Stability of Alatrofloxacin Mesylate in 5% Dextrose Injection and 0.45% Sodium-Chloride Injection
Gupta Vishnu D
, Bailey RE
Jan/Feb 2000
Pg. 66-68

Testosterone Enanthate 200-mg/mL Injection
Allen Loyd V Jr
Mar/Apr 2014
Pg. 151

Case Study: Absorption of Testosterone Cream via Scrotal Delivery
Needham Shawn
, Needham Shane
Nov/Dec 2018
Pg. 466-468

Development and Validation of a Stability-indicating High-performance Liquid Chromatographic Method for Quantification of Progesterone in Compounded Glycerinated Gelatin Troches
Burrows Anna C
, Yellepeddi Venkata Kashyap, Snyder Spencer, Wakefield Meagan, Jackson David, Huynh Johnny, Nguyen Khoa, Sayre Casey L
Jul/Aug 2019
Pg. 340-350

Validation of Ultraviolet-visible and High-performance Liquid Chromatographic Methods for the Determination of Sodium p-Aminosalicylate and m-Aminophenol in a New Pharmaceutical Formulation
Hergert Lisandro Y
, Ravetti Soledad, Mazzieri Maria R
Jan/Feb 2016
Pg. 63-70

High-Performance Liquid Chromatographic Method Optimization for Ondansetron Assay in Extemporaneous Topical Gel and in Marketed Products
Quamrun Masuda
, Mamoon Rashid, Nasheed Shams, Mullins Randy
Nov/Dec 2014
Pg. 520-525

Simple High-Performance Liquid Chromatographic Method for Simultaneous Determination of Fusidic Acid and Betamethasone Dipropionate in a Cream Formulation
Peh Kok-Khiang
, Tan Yvonne Tze-Fung
May/Jun 2000
Pg. 229-231

Testosterone Propionate 100-mg/mL in Oil Injection
Allen Loyd V Jr
May/Jun 2004
Pg. 222

Subcutaneous Testosterone Anastrozole Therapy in Men: Rationale, Dosing, and Levels on Therapy
Glaser Rebecca L
, York Anne E
Jul/Aug 2019
Pg. 325-339

Return to Top